Thursday, December 12, 2024

12 Codes of Christmas - Day 6



On the sixth day of Christmas ASME gave to me 
Remote interaction per 2.26.13


Bet you didn't think elevator professionals could work from home. Whether they're actually at home or at a distant office, the code allows for limited remote interactions with the elevator:
  • The interactions are limited to call and features. The elevator must be in automatic operations.
  • The interactions CANNOT enable, disable, override, reset or otherwise interfere with non-automatic operations.
If remote interaction is possible, a sign must be placed on the controller.

If you have any questions regarding your specific situation, be sure to contact us.

Click here for a complete list of all changes in the 2022 code.