On the first day of Christmas ASME gave to me
A revision to hoistway lighting guidelines per 2.1.1.7
The lighting must be 5 foot candles (ftc) in brightness with switches at the top of the hoistway and at pit access. It must also automatically light, and cannot be turned off by the switches, when:
- The access switch is set to 'Enable'
- The car top switch is set to 'Inspection'
- Firefighter's Emergency Operation (FEO) phase 1 is activated.
Lighting must remain lit via emergency power if necessary.
If the elevator's controller can't adapt to these conditions, it may need to be modernized.
If you have any questions regarding your specific situation, be sure to contact us.
Click here for a complete list of all changes in the 2022 code.