This
is another building we did an incredible modernization project on that improved
the reliability of the elevator system.
We had been talking to the building about equipment replacement since we
took over the account 2012 to start giving them a chance to budget for this
major project.
Existing
elevator & project scope – The existing equipment in the building where
Montgomery Mi Prom 7 story hydraulic elevators.
In Des Plaines, IL there are a lot of MiProms and a lot of US Elevators. Neither MiProm or the US Elevator are user
friendly controller, unless you are a Montgomery or US elevator mechanic that
grew up on these. The good news is that a lot of the existing control systems
are to a point where they are getting replaced.
New
equipment providers
Controllers
– Smartrise Engineering
Power
units – MEI
Door
operators – GAL MOVFR II w/MAC car and hatch door equipment
Fixtures
– Innovation Industries
Hydraulic elevator
controller
– The original controllers have been through a lot including undersized original
mainline disconnect wiring and very hot machine rooms. Look at the difference in how many wires and
boards from the old Miprom control system to the new Smartrise system.
[Old Montgomery MiProm Elevator Controller]
[New Smartrise Elevator Controls]
Hydraulic elevator
power unit
– The old Montgomery power unit was wearing and experiencing fatigue. It also was leaking a decent amount. This replacement was part of phase I which occurred
a few years prior.
[Old Machine room layout]
[New machine room layout - after phase I]
Door operators – The elevator had MAC
operator and equipment. We replaced the
operator with a GAL MOVFR and replaced the existing MAC equipment with new to
reduce some of the expense with replacing with all GAL.
[Old MAC door operator]
[New GAL MOVFR door operator]
Elevator fixtures – The old Montgomery
fixtures went away and new Innovation flush mount fixtures to meet ADA and
elevator code requirements were installed.
Originally there was only 1 button stack so we put the new button stack
on the other elevator to eliminate any downtime. We also combined the directional arrow with a
position indicator because the original man lobby fixture was already busy with
all the devices, when adding the emergency communication, it became challenging
to make everything fit.
[Old first floor fixture layout]
[New first floor fixture layout]
Take away – The big take away
for this project was that a building planned for many years to do the project. We started working with the building in 2015
on budgets and phasing. We broke this
project up into 3 phases many years ago; power units & soft starts, door
operators and finally the control and operating system. Eventually we decided to wait to complete
phase 2 and 3 together and kept the cars running an additional year so it could
all be done at the same time.
Hey! Sign up for our mailing list! Each month you will get
some great info on Colley! It is short
and quick to run through, you’ll like it!