How long should an elevator hydraulic valve last?


How long should a hydraulic control valve last? This is a very good question.  The valve manufacturer states that their valve will last 10-15 years.  Many buildings keep their valves as long as 30-45 years.  The issue with keeping your control valve longer than recommended is you can have reliability issues and leakage. 

Reliability/control – When we have valve reliability issues we cannot control the elevator which means the elevator will not level properly.  We can start to see shut downs or trip and falls when the valve is having reliability issues.

Leakage – A valves parts will begin to leak and this will also cause leveling issues but it will also create a oily mess when it is leaking on the tank or on the floor.

We have elevator control valve manufacturers saying change your valve every 10-15 years, buildings keep their valves sometimes 30-45 years.  We have a huge disparity between these numbers.  Each building’s usage, environment and oil maintenance[replacement, filtration, tank cleaning] is different.  A sleepy building’s elevator valve could last a lot longer than a valve in a hospital or nursing home.  You should consult your elevator contractor on how long your valve will last as there is a safety issue and reliability issues when your control valve is not operating properly.

Here are some pictures of a few building’s I have been to in the last week.  All the buildings have the same elevator, Otis early 1970’s vintage power unit. 

 [This is the original control valve, it appears the elevator contractor is trying to identify where the leaking is coming from or dressing it up for Halloween.  This valve needs to be replaced]

[This control valve has been replaced[not by Colley] but they put the adjustments right up against a pipe so it is very difficult to work on, this probably was faster to install but not easy to work on in the future]

[This is a valve Colley Elevator replaced which took a little extra time to make sure all of the control adjustments are accessible to the elevator mechanic]

Should I replace my oil when I change my control valve? – The answer to this question is yes, unless you have changed your oil recently prior to the valve replacement.  We will address hydraulic oil maintenance in a future post.  Or you can see a post from a few years ago.

http://colleyelevator.blogspot.com/2016/05/cleaning-elevator-hydraulic-fluid.html

If you have any questions or would like additional information feel free to contact me at CraigZ@colleyelevator.com or 630-766-7230 ext. 107.

Also check us out on Instagram @Colleyelevator see what we have been up to.

5 comments:

  1. I really like your Blog. Thanks to Admin for Sharing such useful information. Addition to this here I am sharing one more similar Story Pneumatic actuator supplier

    ReplyDelete
  2. I have read your article it is really good and informative to me. Keep posting this kind of article hydraulic valve repair near me

    ReplyDelete
  3. We are a quality conscious parts manufacturer, based in Narol area of Ahmedabad, Gujarat, India. We manufacture un-machined and machined grey cast iron castings from 200 grams to 120 kilograms.
    We have a full fledged machine shop having CNC lathes and vertical machining centres for precision machining of parts from various types of engineering materials like CI, alloy steels, stainless steel, engineering plastics, non ferrous metals.
    Elevator Parts manufacturing in Ahmedabad

    ReplyDelete
  4. Thanks for sharing this wonderful blog with us. Nice post with great information and it is indeed informative and useful.

    Pressure Safety Valve China

    ReplyDelete