Sunday, October 1, 2017

NAEC – 2017 elevator convention – Atlantic City



We had a convention scheduled for Orlando, FL.  A hurricane called Irma came and 12 days later nothing short of a miracle occurred and we had a convention in Atlantic City, NJ.  For those who do not know a convention takes about 2 years to schedule so making these changes in such a short amount of time was amazing.  Hats off to the NAEC staff and exhibitors for doing the heavy lifting to make this occur.

[Show floor]

Once a year North America convenes to the NAEC convention where almost 200 exhibitors show their products and services.  Due to the dramatic move there was 143 in Atlantic City who came.  This is a great time to see product and services but also get some education.

There where round tables featuring information on employment law, best practices, insurance costs, mobile technology, A18.1 code update, safety compliance templates & new hiring orientation.

[NFPA update by Lee Rigby]

There where speakers on maximizing rope life, retaining DC machines, control of hazardous energy, roller guides, fire code changes, risk & liability in phone monitoring, inclined platform lifts and vertical platform lifts, confined space, mechanics guide to safety inspections, elevator drives and competing in the proprietary market.  Some of which qualified for CEUs.

[Reception prior to dinner dance]

There where some receptions, a great dinner dance, a chance for the next generation of elevator people to get together for lunch and finally the dregs party which was at Bass Pro shop[which was surprisingly great].

It was a long week, but all and all it was an incredible convention and I appreciate everyone’s hard work[NAEC staff] that put it on as well as the exhibitors who participated.  I learned a lot from the scheduled events and got a chance to talk to suppliers and contractors all over the country about what is occurring in their areas.  I always take away a lot from this event.  

 [I did have one free night open]

Next year’s event will be in Atlantic City.  Go to http://www.naec.org/ for more information.  


As always feel free to contact us at www.colleyelevator.com, email Craigz@colleyelevator.com or call 630-766-7230.

Sunday, September 24, 2017

Readable Fireman’s phase I & II instructions

In the past, I would get an inspectors write up indicating the halos needed to be changed on the Fireman’s phase I & II instructions.  I believe this to be more of a nuisance write up then a legitimate one.  Over the years of sitting in educational events and completing training for first responders[fire departments], I realized the importance of having clearly marked instructions.  After doing fire department training I realized that all fireman are not trained in running cars on fireman’s service, they do not know it by heart and the instructions may be imperative.  If a fireman is in the car he is thinking about getting the elevator to the floor he or she needs to get to so it is important that key switches are marked clearly and instructions are legible.

 [Fireman's service phase II instructions are hard to read on the muntz/bronze back ground]
    [Call cancel button fogged & cracked, phase II switch postion markings are worn away]

What made me think of this is being at a hotel where I had a hard time reading the key switch and instructions.  The deterioration of the markings are most likely from years of using cleaning solution to clean the car station.

Take away – If you are a building owner or an elevator maintenance professional be aware of the FEO instructions and if needed get new instructions and new halos so if there is an emergency the first responders can use the FEO properly quickly.  While hopefully FEO will never need to be used in an emergency, if it is needed time is of the essence and it could be the difference between life and death.


As always feel free to contact us at www.colleyelevator.com, email Craigz@colleyelevator.com or call 630-766-7230.

Sunday, September 17, 2017

Staying safe – Elevator worker safety

There was a 2nd accident on September 8th in Toronto that took a life of an elevator mechanic in the last two weeks. Please be careful out there.

https://www.thestar.com/news/gta/2017/09/09/man-52-second-worker-to-be-killed-in-elevator-accident-in-last-two-weeks.html


As always feel free to contact us at www.colleyelevator.com, email Craigz@colleyelevator.com or call 630-766-7230.

Sunday, September 10, 2017

Staying Sharp – Continuing education for elevator professionals

Last week we had our annual 10 hour continuing education course on the elevator code.  We had over 30 elevator professionals at our training area to get their CEU’s for State Licensing or QEI.  While it is always 10 hours and is a long day, I do enjoy this class.



When we graduate high school, associate’s degree, college, union school, trade school, grad school, etc there is a thought that we do not need to continue our learning.  “I just finished school, I’m good” this is wrong.  As technology changes, as codes and rules change, as changes become faster and faster, it is imperative that we spend the time learning.  Lifelong learning needs to be in everyone’s vocabulary.

This is an exciting year for the Illinois area.  The State is adopting A17.1 2016, The City of Chicago is adopting A17.1 2016, there are FEO mandates looming around, there are future mandates on the horizon.  You learn about these new things by putting your butt in the seat.

As inspectors, elevator inspectors, sales people and support staff it is very important we are aware of new technology and code changes.  It makes our jobs easier, makes advancement easier and helps us master our craft.  When we master our craft it takes a job and turns it into a passion.

I am a huge proponent of continuing education and lifelong learning and encourage everyone in whatever industry you are in to always continue to learn and challenge yourself to learn new things.  At times learning is uncomfortable and you may feel like you are never going to know or master these ideas.  This is a common feeling, just like in grade school, you will catch on and things will begin to click. But if you do not try, if you do not take the time to learn, if you do not try and advance your skill set, you are limiting yourself.  By not trying you will never fail at that task, but you will fail at reaching your potential.

Where do I find learning?  NAEC, NAESA, CECA, CEA, NEIEP and other elevator organizations offer opportunities on a regular basis.  We all can miss a few episodes of Everyone Loves Raymond or How I met your Mother, both shows will be here when you get back.


As always feel free to contact us at www.colleyelevator.com, email Craigz@colleyelevator.com or call 630-766-7230.

Tuesday, September 5, 2017

Elevator pit hazards & safe access

There have been some recent accidents involving elevator pits.  Pit safety is one thing that is of the utmost importance but we at times are complacent. This posting will be vague as non-elevator personnel should not be entering pits.  It is intended to be a refresher and remind us of close calls we have heard of or experiences so we do not repeat them.

Pit hazards

1.    Inadequate refuge space
2.    Inadequate lighting
3.    Improper access
4.    Tripping hazards
5.    Unsafe or lack of pit ladder
6.    Moisture/water/oil
7.    Moving equipment

[example of pristine pit conditions elevator mechanics run into]

One of the more important items is planning, look at the pit, identify the key pieces of elevator equipment and safety equipment as well as refuge area.  As we see in the picture sometimes there is a lot going on in a pit.

Lock out tag outs are a big item we need to remember to do when we are not needing to move an elevator to perform work.

Barricade the hoist way door if it going to be open more than 5”.  Even with two people performing a task, the 2nd person always tends to have to get something, be aware of this item.

Be aware of the hoistway door unlocking device pinch points if the door is under power.  If you haven’t experienced this, try your best not to, it isn’t pleasant.

Always be aware of the stop switch location and its position.

Always test the stop switch to make sure it actually works.

Never stand on a pit aldder when the pit stop switch is in the on position.

The Elevator Safety Handbook has processes for accessing a pit safely that goes into depth on the correct way to complete this task.  I wanted to list the high points that we may be over confident in.


As always feel free to contact us at www.colleyelevator.com, email Craigz@colleyelevator.com or call 630-766-7230.

Monday, August 21, 2017

Elevator machine room temperatures

This summer we have seen more frequent failure of solid state boards and equipment that has been exposed to extreme heat and extreme cold.  Building owners frequently ask “why is this occurring”.   I always like to give some research and background when explaining to building owners so they can be better educated and came across a great article which I have taken some of the high points.  When reading this be aware that most issues with machine room environments will result in a shut down or needing a replacement board, but, incorrect machine temperatures can also cause malfunctions which could result in an elevator operating in an unsafe condition.

The subject of the operation of an elevator in an elevated high ambient machine room temperature is one of concern of elevator manufacturers, code writes, enforcing authorities, building owners, and operators, elevator consultants and fire safety personnel.  Today’s solid-state design elevator control systems are able to maintain rated performance over a wide range of normal design operating temperature, but are vulnerable to elevated temperature conditions.

NEII Vertical Transportation Standard calls for machine room/or machinery spaced temperature to be between 55 and 80 degrees Fahrenheit

NEMA has established a maximum temperature limit of 104 degrees Fahrenheit.

National Electrical Code[NEC] has published 86 degrees Fahrenheit as the standard ambient for conductor ampacity ratings.

Computer manufacturers recommend an ambient temperature of 60 to 90 degrees Fahrenheit.

The effects on solid state components due to temperature may be classified in two areas; operating[reliability] and failure[life].  The manufacturers recommendation for ambient temperature will allow the devices to operate in a repeatable and predictable fashion.  Temperatures above or below the recommended temperature will decrease the life of the solid-state system.

Please note - Elevator controller temperatures are 10 to 15 degrees warmer inside the controller with the cover on. If an elevator machine room is 105 degrees the temperature when you open the door, the controller could be over 120 degrees.

Causes of machine room over temperature
1.    Failure of machine room ventilation or no ventilation
2.    Failure of cabinet ventilation system – air condition or fan
3.    Increase in the elevator duty cycle beyond design criteria
4.    Sustained operation at low AC input levels

The recommendation of machine room temperature control come from a few different areas
1.    Normal temperature in room – In Chicago we have hot summers and cold winters
2.    Amount of heat released from the elevator equipment in the machine room – depends on the equipment you have and amount of traffic in the building
3.    Amount of ventilation and/or air conditioning/heating provided in machine room.

Take away – Be aware of the machine room environment and make preparations i.e. air conditioning[best case] or ventilation in summer and heating in the winter.

Reference – “High temperature operation of elevators” by Nick Marchitto


As always feel free to contact us at www.colleyelevator.com, email Craigz@colleyelevator.com or call 630-766-7230.

Sunday, August 6, 2017

Colley Elevator summer get together

Colley Elevator had its first of hopefully many summer get togethers.  This was a special one because we celebrated two long term employees upcoming retirement at the Chicago White Sox game.  We had 99 people attend the game with us.  We have two great people who will be moving on to their next part of life.  As coworkers we spend so much time together and get to know one another very well, this makes it exciting to see them move on.  Together we have 73 years of Colley experience leaving us, I am very happy we all got to share our time together!  

Both have known me since I was very little.  I worked side by side with Aida for 17 years in the office.  Dennis has guided me through understanding field work and has been my partner in the business for the last 10 years

 [This is a picture of the scoreboard!  Thanks Chuck!]

                                           [A group picture taken by Aida's son]


Thank you Dennis and Aida you will be missed!

As always feel free to contact us at www.colleyelevator.com, email Craigz@colleyelevator.com or call 630-766-7230.